Data modelMPMeasurement

Measurement

id

Description: Unique ID to be used as a link target
Required: yes
Path: metadata.method_specific_parameters.measurements.id
Type: link target (string)

name

Description: Name (id) of the measurement which must be unique within a record (i.e. triplicates must be named individually in the raw data file). The name must allow location of the measurement data within the raw data file as well as processed data files if these are present
Required: yes
Path: metadata.method_specific_parameters.measurements.name
Type: string

duration

Description: The time duration of the measurement
Required: yes
Path: metadata.method_specific_parameters.measurements.duration
Type: object (Duration)
Contains: see Duration

temperature

Description: The temperature the measurement was performed at
Required: yes
Path: metadata.method_specific_parameters.measurements.temperature
Type: object (Temperature)
Contains: see Temperature

sample

Description: Information about the sample including concentrations and which chemical environment the sample was composed of
Required: yes
Path: metadata.method_specific_parameters.measurements.sample
Type: object (Sample)
Contains: see Fields available in sample

Fields available in sample

targets

Description: Information about the sample including concentrations of ligands and targets, and which chemical environment the sample was composed of
Required: yes
Path: metadata.method_specific_parameters.measurements.sample.targets
Type: object (Entity_constituent)
Contains: see Entity_constituent

chemical_environments

Description: Name (id) of the chemical environment of the sample (from the chemical environments defined in the record)
Required: yes
Path: metadata.method_specific_parameters.measurements.sample.chemical_environment
Type: link
Link Target: Chemical environment

preparation_protocol

Description: List of steps taken to prepare the sample, ending at the point where it was placed in the measurement container. Information include operations like filtration and which filter material and pore-size was used should be added
Required: no
Path: metadata.method_specific_parameters.measurements.sample.preparation_protocol
Type: array of object (Step)
Contains: See Step

sample_dilution

Description: Parameters describing how the sample was diluted within the measurement in flow mode’
Required: no
Type: object (MP_sample_dilution)
Path: metadata.method_specific_parameters.measurements.sample_dilution
Contains: See MP sample dilution